However, key issues exist related to device cost, service, maintenance, and more. 5 presented methods using external devices. Dawood et al., 2 Qiao et al., 3 Lamare et al., 4 and Liu et al. The current clinical standard uses external measuring devices to extract respiratory signals from the patient. 1 Respiratory motion is particularly problematic for PET due to typical scan times of 2–5 min (8–20 min for whole-body scans), leading to averaging of the image pixel values across the range of motion. Along with blurring and otherwise degraded image quality, motion artifacts may result in inaccurate localization of lesions, miscalculation of standardized uptake values (SUVs), and overestimation of tumor size and involvement. Motion artifacts caused by the natural breathing of the patient during a scan are a major concern. Positron emission tomography (PET) is a noninvasive imaging modality widely used in clinical application to study organ and tissue function and is used most often in conjunction with computed tomography (CT) to acquire anatomical information and for emission data correction. The algorithm has the potential to facilitate true motion correction where the reconstruction algorithm can use all data available. Gating based on the motion estimate is shown to quantifiably improve the image quality in both a controlled point source phantom study and in clinical data patient studies. ConclusionĪ PEPT- based algorithm has been presented for determining movement due to respiratory motion during PET/CT imaging. In addition, max SUVs were found to be 4–10% higher in the TOF-PEPT-based gated images than in those based on Anzai and COM methods. The distinct presence of lesions with reduced blurring effect and generally sharper images were readily apparent in all clinical studies. In comparison with the ungated image, a 14–39% increase in the max SUV across several lesion areas and an 8.7% increase in the max SUV on the tracked lesion area were observed in the gated images based on TOF-PEPT. Maximum Standardized Uptake Values (SUVs) were used to quantitatively compare the reconstructed-gated images. TOF-PEPT was found to be 13–38% better correlated with the Anzai results than the COM methods. The derived motion signals correlated well with the Anzai band correlation coefficients of 0.99 and 0.94-0.97 were obtained for the phantom study and the clinical studies, respectively. The TOF-PEPT algorithm is shown to successfully determine the respiratory motion for both phantom and clinical studies. Using the motion estimate from each method, amplitude-based gating was applied, and gated images were reconstructed. For the purposes of additional comparison, a center-of-mass (COM) algorithm was implemented both with and without the use of TOF information. The extracted motion signals were compared with the Anzai band when applicable. The motion tracking was performed using a preselected region of interest (ROI), manually drawn around point sources or lesions on reconstructed images. For studies with radioactive point sources, they were placed on patients during PET/CT imaging. The TOF-PEPT algorithm was implemented and investigated under different scenarios: (a) a phantom study with a point source and an Anzai band for respiratory motion tracking (b) a phantom study with a point source only, no Anzai band (c) two clinical studies with point sources and the Anzai band (d) two clinical studies with point sources only, no Anzai band and (e) two clinical studies using lesions/internal regions instead of point sources and no Anzai band. This paper introduces a time-of-flight (TOF)-weighted positron emission particle tracking (PEPT) algorithm that facilitates lesion-specific respiratory motion estimation from raw listmode PET data. Data-driven techniques are an active area of research with limited exploration into lesion-specific motion estimation. Hardware-based motion estimation, which is the current clinical standard, requires initial setup, maintenance, and calibration of the equipment, and can be associated with patient discomfort. Respiratory motion of patients during positron emission tomography (PET)/computed tomography (CT) imaging affects both image quality and quantitative accuracy.
0 Comments
Includes a how-to video and a printable training manual. #Heat shrink wrap how to#How To Shrink Wrap Large Objects Video: How To Guide for Containment: This step-by-step guide teaches the Pro-Tect Plastics Environmental Containment Process for shrink wrapping around scaffolding on a construction project. They are available in 6" or 12" width with 225' length and 1/4" thickness. Made of MIL-SPEC tubing that is flame-retardant, abrasion-resistant. 13 MM - 1 Roll 3.5 out of 5 stars 13 14.9514.95 (0. PRT is a wrap-around heat shrink that is engineered for the most rugged of conditions. They are see through and add a distinctive color appeal to your product. #Heat shrink wrap free#Poly Foam Padding: Our high density poly foam is used for padding sharp corners or other parts that could potentially puncture the shrink wrap film. 28.99 (8 new offers) Kable Kontrol Heat Shrink Wrap Tape/Adhesive - 1' Inch Wide - 16.5 Ft Rolls - Black 3.6 out of 5 stars 64 22.9322.93 (1.39/Sq Ft) FREE delivery Oct 11 - 13 Small Business Sherco-Auto Black Heat Shrink Tape 1 x 180' (60 Yards) x. Colored PVC Shrink Wrap Film Colored shrink wrap available in red, green, gold. They are particularly effective for moisture control during transport. Pro-Tect Plastics sells plastic vents with adhesive backing that have a 4” outer diameter and 1 ¾” inner hold diameter.ĭesiccant Bags: These 300 gram bags are used to reduce moisture and condensation under a sealed shrink wrapped object or boat when venting is not used. A wrap-around, abrasion-resistant, fluid-resistant heat shrink that repairs wires or cables with diameters up to 0.5. Midwest Crating Unlimited offers heat-shrink wrapping services to protect cargo from the elements during transport, and allows items to be stored both short. Ventilation reduces condensation and mildew growth during storage. Long (2-Pack) Not only do damaged wires lead to power interruptions, but they can also pose serious safety hazards. Stick On Vents: Easily ventilate your shrink wrapped boat or equipment with stick on vents. Long (4-Pack) Heat Shrink Black Tubing, 2:1 Shrink Ratio 3/4 in., 3 In. We will be happy to help you find everything you need. If you don’t see a shrink wrap accessory or supply that you need, please call or email us. Even if the grip material is intact, since our textured grip heat shrink comes in multiple colors ( such as Black, Blue, Green, Red, or Yellow), you can better organize your equipment. 1 Set 127PCS/Set Heat Shrink Tubing Electrical Wrap Wire Cable Sleeves PE 2:1 Insulated Sleeving Assorted. Pro-Tect Plastics has all of the supplies, accessories, equipment, and guides you need to complete your shrink wrap project. Uxcell PVC Heat Shrink Tubing 33.46' Flat Width Pre Cut Heat Shrink Wrap Tube for Four 18650 6.56 ft Long Blue. PVC (20) Polyethylene (2) Polyolefin (21) Thickness. Order the shrink wrap supplies and equipment needed to complete your project here. Home All Products Material Handling Packaging & Shipping Products Heat Activated Shrink Wrap & Equipment Shrink Wrap Films Filter Results. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |